Carpet Manufacturing, Wash Box Stations

A carpet manufacturing facility wanted to replace the current heat exchanger with a better water heating solution for their wash box station. They were looking for:

  • Energy efficiencies
  • Better temperature control
  • Better turn down control and capabilities

Design Conditions

Water Flow Rate: 200 gpm
Water Inlet Temperature: 50°F
Water Outlet Temperature: 110°F
Water Inlet Pressure: 85 psig
Steam Pressure: 100 psig


For more EZ Heater product and design information, please click here.

Hydro-Thermal Solution

Hydro-Thermal’s EZ Heater model H2030.
An H2030 with a Large (L) diffuser was installed. The customer has realized the inherent advantages of its design.

♦ Easy installation and replacement of technologies
♦ 28% more efficient than the heat exchanger
♦ Instantaneous hot water on demand at exact temperatures +/- 1°F
♦ Excellent turn down control and capabilities
♦ Patented self-cleaning design to prevent scaling and fouling
 

Click here to download an Adobe Acrobat document containing this case study information.
 
 
Contact: 800.952.0121 | 262.548.8900